| MINIMUM PLUMBING FIXTURES -1994 Southern Plumbing Code | |||||
| Schools: Elementary/Secondary | |||||
| Number | Total Male | Total Female | |||
| Students | Water | Lavatories | Urinals | Water | Lavatories |
| Closets | Closets | ||||
| 25 | 1 | 1 | 1 | 2 | 1 |
| 50 | 1 | 1 | 1 | 2 | 1 |
| 75 | 2 | 1 | 2 | 3 | 1 |
| 100 | 2 | 1 | 2 | 3 | 1 |
| 125 | 2 | 2 | 2 | 4 | 2 |
| 150 | 2 | 2 | 2 | 4 | 2 |
| 175 | 3 | 2 | 3 | 5 | 2 |
| 200 | 3 | 2 | 3 | 5 | 2 |
| 225 | 3 | 2 | 3 | 6 | 2 |
| 250 | 3 | 3 | 3 | 6 | 3 |
| 275 | 4 | 3 | 4 | 7 | 3 |
| 300 | 4 | 3 | 4 | 7 | 3 |
| 325 | 4 | 3 | 4 | 8 | 3 |
| 350 | 4 | 3 | 4 | 8 | 3 |
| 375 | 5 | 4 | 5 | 9 | 4 |
| 400 | 5 | 4 | 5 | 9 | 4 |
| 425 | 5 | 4 | 5 | 10 | 4 |
| 450 | 5 | 4 | 5 | 10 | 4 |
| 475 | 6 | 4 | 6 | 11 | 4 |
| 500 | 6 | 5 | 6 | 11 | 5 |
| 525 | 6 | 5 | 6 | 12 | 5 |
| 550 | 6 | 5 | 6 | 12 | 5 |
| 575 | 7 | 5 | 7 | 13 | 5 |
| 600 | 7 | 5 | 7 | 13 | 5 |
| 625 | 7 | 6 | 7 | 14 | 6 |
| 650 | 7 | 6 | 7 | 14 | 6 |
| 675 | 8 | 6 | 8 | 15 | 6 |
| 700 | 8 | 6 | 8 | 15 | 6 |
| 725 | 8 | 7 | 8 | 16 | 7 |
| 750 | 8 | 7 | 8 | 16 | 7 |
| 775 | 9 | 7 | 9 | 17 | 7 |
| 800 | 9 | 7 | 9 | 17 | 7 |
| 825 | 9 | 7 | 9 | 18 | 7 |
| 850 | 9 | 8 | 9 | 18 | 8 |
| 875 | 10 | 8 | 10 | 19 | 8 |
| 900 | 10 | 8 | 10 | 19 | 8 |
| 925 | 10 | 8 | 10 | 20 | 8 |
| 950 | 10 | 8 | 10 | 20 | 8 |
| 975 | 11 | 9 | 11 | 21 | 9 |
| 1000 | 11 | 9 | 11 | 21 | 9 |
| Occupancy: Average Daily Attendance | |||||
| Drinking Fountains = 1 per Classroom, Not less than one per floor | |||||
| Whorton Engineering, Inc. assumes no responsibility for the | |||||
| accuracy of this data. Data is provided for reference purposes only! | |||||