MINIMUM PLUMBING FIXTURES - 1994 Southern Plumbing Code
Retail Stores
Water Closets Lavatories Drinking Fountains
Number Male Female Number Male Female Number Qty.
Occupants     Occupants     Occupants Req'd.
1-35 1 1 1-15 1 1 1-100 1
36-55 1 2 16-35 1 2 101-250 2
56-80 2 3 36-60 2 2 251-500 3
81-100 2 4 61-125 2 3 See Notes  
101-150 2 5   3      
175 3 6 175 3 4    
200 3 6 200 3 4    
225 3 6 225 3 5    
250 3 6 250 4 5    
275 3 7 275 4 5    
300 3 7 300 4 6    
325 3 7 325 4 6    
350 3 7 350 4 6    
375 4 7 375 5 7    
400 4 8 400 5 7    
425 4 8 425 5 7    
450 4 8 450 5 8    
475 4 8 475 5 8    
500 4 9 500 6 8    
525 4 9 525 6 8    
550 4 9 550 6 9    
575 5 9 575 6 9    
600 5 9 600 6 9    
625 5 10 625 7 10    
650 5 10 650 7 10    
675 5 10 675 7 10    
700 5 10 700 7 11    
725 5 11 725 7 11    
750 5 11 750 8 11    
Occupant Content = 200 SF/Person        
A single facility consisting of one water closet and one lavatory may    
be used by both male and females if the maximum building area  
is less than 1200 SF.            
Above  an Occupancy of 500 the Plumbing Code does not specify    
the number of drinking fountains          
Drinking Fountains can not be less than one per floor.      