| MINIMUM PLUMBING FIXTURES - 1994 Southern Plumbing Code | |||||||
| Retail Stores | |||||||
| Water Closets | Lavatories | Drinking Fountains | |||||
| Number | Male | Female | Number | Male | Female | Number | Qty. |
| Occupants | Occupants | Occupants | Req'd. | ||||
| 1-35 | 1 | 1 | 1-15 | 1 | 1 | 1-100 | 1 |
| 36-55 | 1 | 2 | 16-35 | 1 | 2 | 101-250 | 2 |
| 56-80 | 2 | 3 | 36-60 | 2 | 2 | 251-500 | 3 |
| 81-100 | 2 | 4 | 61-125 | 2 | 3 | See Notes | |
| 101-150 | 2 | 5 | 3 | ||||
| 175 | 3 | 6 | 175 | 3 | 4 | ||
| 200 | 3 | 6 | 200 | 3 | 4 | ||
| 225 | 3 | 6 | 225 | 3 | 5 | ||
| 250 | 3 | 6 | 250 | 4 | 5 | ||
| 275 | 3 | 7 | 275 | 4 | 5 | ||
| 300 | 3 | 7 | 300 | 4 | 6 | ||
| 325 | 3 | 7 | 325 | 4 | 6 | ||
| 350 | 3 | 7 | 350 | 4 | 6 | ||
| 375 | 4 | 7 | 375 | 5 | 7 | ||
| 400 | 4 | 8 | 400 | 5 | 7 | ||
| 425 | 4 | 8 | 425 | 5 | 7 | ||
| 450 | 4 | 8 | 450 | 5 | 8 | ||
| 475 | 4 | 8 | 475 | 5 | 8 | ||
| 500 | 4 | 9 | 500 | 6 | 8 | ||
| 525 | 4 | 9 | 525 | 6 | 8 | ||
| 550 | 4 | 9 | 550 | 6 | 9 | ||
| 575 | 5 | 9 | 575 | 6 | 9 | ||
| 600 | 5 | 9 | 600 | 6 | 9 | ||
| 625 | 5 | 10 | 625 | 7 | 10 | ||
| 650 | 5 | 10 | 650 | 7 | 10 | ||
| 675 | 5 | 10 | 675 | 7 | 10 | ||
| 700 | 5 | 10 | 700 | 7 | 11 | ||
| 725 | 5 | 11 | 725 | 7 | 11 | ||
| 750 | 5 | 11 | 750 | 8 | 11 | ||
| Occupant Content = 200 SF/Person | |||||||
| A single facility consisting of one water closet and one lavatory may | |||||||
| be used by both male and females if the maximum building area | |||||||
| is less than 1200 SF. | |||||||
| Above an Occupancy of 500 the Plumbing Code does not specify | |||||||
| the number of drinking fountains | |||||||
| Drinking Fountains can not be less than one per floor. | |||||||
| Whorton Engineering, Inc. assumes no liability for the | |||||||
| accuracy of this data. Data is provided for reference purposes only! | |||||||